Raman Spectroscopic Systems

Robust optical measurement of chemical composition.

1 - 25 of 25 Products
Raman Rxn-20 probe
Endress+Hauser
Raman Rxn-20 probe
Extended Extended
Request Information
Raman Calibration Tool
Endress+Hauser
Raman Calibration Tool
Extended Extended
Request Information
Raman Rxn-40 Probe
Endress+Hauser
Raman Rxn-40 probe
Extended Extended
Request Information
Raman Rxn-10 Probe
Endress+Hauser
Raman Rxn-10 probe
Extended Extended
Request Information
Raman Rxn-41 Probe
Endress+Hauser
Raman Rxn-41 probe
Extended Extended
Request Information
Raman Rxn5 Process Analyzer
Endress+Hauser
Raman Rxn5 process analyzer
Extended Extended
Request Information
Raman Rxn-46 Probe
Endress+Hauser
Raman Rxn-46 probe
Extended Extended
Request Information
Raman Rxn2 Mobile Cart
Endress+Hauser
Raman Rxn2 mobile cart
Extended Extended
Request Information
Raman Bio Sleeve
Endress+Hauser
Raman bio sleeve
Extended Extended
Request Information
Raman Rxn-30 Probe
Endress+Hauser
Raman Rxn-30 probe
Extended Extended
Request Information
Raman Electro-Optical (EO) Fiber Optic Cables
Endress+Hauser
Raman electro-optical (EO) fiber optic cables
Extended Extended
Request Information
Raman Optic System for Single Use
Endress+Hauser
Raman optic system for single use
Xpert Xpert
Request Information
Raman Rxn2 Analyzer
Endress+Hauser
Raman Rxn2 analyzer
Extended Extended
Request Information
Raman Rxn-20 Probe Accessories
Endress+Hauser
Raman Rxn-20 probe accessories
Extended Extended
Request Information
Raman bIO-Optics
Endress+Hauser
Raman bIO-Optics
Extended Extended
Request Information
Raman Immersion Optic
Endress+Hauser
Raman immersion optic
Extended Extended
Request Information
Raman Bio Multi Optic
Endress+Hauser
Raman bio multi optic
Extended Extended
Request Information
Raman Enclosed Sample Compartment
Endress+Hauser
Raman enclosed sample compartment
Extended Extended
Request Information
Raman Rxn4 Analyzer
Endress+Hauser
Raman Rxn4 analyzer
Extended Extended
Request Information
Raman Calibration and Verification Kits
Endress+Hauser
Raman calibration and verification kits
Extended Extended
Request Information
Raman Calibration Accessory
Endress+Hauser
Raman calibration accessory
Extended Extended
Request Information
Raman Flow Bench
Endress+Hauser
Raman flow bench
Extended Extended
Request Information
Raman Non-Contact Optics
Endress+Hauser
Raman non-contact optics
Extended Extended
Request Information
Raman Rxn-45 Probe
Endress+Hauser
Raman Rxn-45 probe
Extended Extended
Request Information
Raman Flow Cell
Endress+Hauser
Raman flow cell
Extended Extended
Request Information

Raman Spectroscopic Systems

Raman spectroscopic systems are optical analyzers that measure chemical composition using Raman scattering, enabling direct insight into molecular structure and concentration. They are valued for robust, precise measurement data that supports continuous visibility into critical operations. A defining advantage is real-time, in situ analysis that can deliver laboratory-grade insight while scaling cost-effectively into production environments.

Typical configurations use a laser source, a spectrometer, and fiber-optic probes that place the measurement interface directly at the process boundary. Probes can be deployed inline, online, or at-line depending on process constraints, and they are often used where traditional sampling is slow, hazardous, or prone to contamination. Chemometric models commonly translate spectra into concentrations and quality attributes, enabling multivariate monitoring without repeated wet-chemistry tests.

Benefits include faster process understanding, reduced sampling burden, and improved control of complex chemistries. Continuous compositional feedback supports tighter endpoint detection, improved batch-to-batch consistency, and earlier identification of deviations. The ability to monitor multiple components simultaneously can reduce the need for multiple dedicated sensors and improve overall analytical coverage without increasing sampling complexity.

Applications span chemical processing and life sciences, including reaction monitoring, crystallization and polymorph control, solvent and concentration tracking, and bioprocess monitoring in bioreactors. Raman platforms are broadly positioned across sectors such as chemical, life sciences, food and beverage, and oil & gas/marine, reflecting the technique’s versatility for composition and concentration measurement.

Key specification factors include probe wetted materials, optical window management, laser wavelength selection, and the calibration/validation plan for chemometric models. Practical design choices - probe insertion geometry, fouling mitigation, and safe laser management - strongly influence reliability. Integration with automation systems and data infrastructure should support both real-time control use cases and longer-term model maintenance.

Engineered Equipment Company, a leading supplier of specialized industrial equipment.