pH Sensors & Transmitters

Products for high-quality pH measurement in all industries.

1 - 48 of 80 Products
Multiparameter Handheld Liquiline Mobile CML18
Endress+Hauser
Liquiline Mobile CML18_s_stehend_001.png
Lean Lean
Request Information
Digital pH Sensor Memosens CPL51E
Endress+Hauser
CPL51E_s_20.01._001.png
Fundamental Fundamental
Request Information
Analog pH Sensor Orbipore CPS91
Endress+Hauser
cps91 spitze.png
Request Information
Multichannel Multiparameter Software Memobase Plus CYZ71D
Endress+Hauser
CYZ71D.png
Request Information
Combined pH/ORP Sensor Memosens CPS76E
Endress+Hauser
CPS76E-combined-pH-ORP-sensor.png
Extended Extended
Request Information
Digital pH Sensor Orbisint CPS11D
Endress+Hauser
CPS11D_Ex_front.png
Extended Extended
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA474
Endress+Hauser
CPA474.png
Request Information
Digital pH Sensor Memosens CPS71E
Endress+Hauser
CPS71E-pH-sensor.png
Extended Extended
Request Information
Digital pH Sensor Memosens CPS11E
Endress+Hauser
CPS11E-pH-sensor-ion-trap-ex-version-straight.png
Extended Extended
Request Information
Ex-Certified Multiparameter Handheld Liquiline To Go CYM291
Endress+Hauser
LiquilineTo Go CYM291.png
Request Information
Digital Non-Glass pH Sensor Ceramax CPS341D
Endress+Hauser
cps341d_ceramax gerade.png
Extended Extended
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA875
Endress+Hauser
CPA875_pneumatic_measuring_position.png
Request Information
Process Assembly Ecofit CPA640
Endress+Hauser
CPA640.png
Request Information
pH Buffer CPY20
Endress+Hauser
CPY20 pH buffers.png
Request Information
Digital Service Tool Memocheck CYP02E
Endress+Hauser
Digital service tool Memocheck CYP02E
Request Information
Digital pH Sensor Memosens CPL59E
Endress+Hauser
Memosens CPL59E.png
Request Information
Analog pH Sensor Ceraliquid CPS41
Endress+Hauser
cps41 - mit TOP68.png
Request Information
Cleaning Unit Cleanfit Control CYC25
Endress+Hauser
Cleaning unit Cleanfit Control CYC25
Request Information
Flow Assembly for Multi-Parameter Measurements Flowfit CYA27
Endress+Hauser
Flow assembly for multi-parameter measurements Flowfit CYA27
Request Information
4-Channel Transmitter Liquiline CM444
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Liquiline Edge Module CYY7
Endress+Hauser
Liquiline Edge Module CYY7
Extended Extended
Request Information
Digital pH Sensor Memosens CPS31E
Endress+Hauser
CPS31E-pH-sensor-salt-storage.png
Extended Extended
Request Information
Flow Assembly Flowfit CYA21
Endress+Hauser
CYA21_Durchflussarmatur 71042404_g_001.png
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA871
Endress+Hauser
cpa871_peek_immersion_chamber_manual.png
Request Information
Analog pH Sensor Ceragel CPS71
Endress+Hauser
cps71-pH-sensor-front.png
Request Information
Analog pH Sensor Ceratex CPS31
Endress+Hauser
CPS31_pH_sensor_angular.png
Request Information
1-Channel Transmitter Liquiline Compact CM82
Endress+Hauser
Liquiline Compact CM82_angular.png
Request Information
Digital pH Sensor Memosens CPS171D
Endress+Hauser
CPS171D_front.png
Extended Extended
Request Information
Manual Retractable Assembly Cleanfit CPA450
Endress+Hauser
CPA450.png
Request Information
Digital pH Sensor Ceraliquid CPS41D
Endress+Hauser
cps41d - Ex - cmyk.png
Request Information
Immersion Assembly Dipfit CPA111
Endress+Hauser
CPA111_front.png
Request Information
Digital pH Sensor Memosens CPF81E
Endress+Hauser
CPF81E-digital-pH-sensor.png
Extended Extended
Request Information
1-/2-Channel Transmitter Liquiline CM442R
Endress+Hauser
CM442R.png
Extended Extended
Request Information
1-Channel Transmitter Liquiline M CM42
Endress+Hauser
CM42_plastic version_angular.png
Extended Extended
Request Information
4-Channel Transmitter Liquiline CM444R
Endress+Hauser
CM444R.png
Extended Extended
Request Information
Analog pH Sensor Purisys CPF201
Endress+Hauser
cpf201-purisys 03.png
Request Information
1-/2-Channel Transmitter Liquiline CM442
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Flow Assembly Flowfit CPA25
Endress+Hauser
Flow assembly Flowfit CPA25
Lean Lean
Request Information
Digital pH Sensor Ceragel CPS71D
Endress+Hauser
CPS71D-G-7TB21.png
Extended Extended
Request Information
Digital pH Sensor Orbipac CPF81D
Endress+Hauser
CPF81D-pH-sensor-angular.png
Request Information
Immersion Assembly Flexdip CYA112
Endress+Hauser
CYA112_Rendering_2.png
Request Information
Immersion Assembly Dipfit CPA140
Endress+Hauser
CPA140_front.png
Request Information
Analog pH Sensor Orbipac CPF81
Endress+Hauser
cpf81_analog_pH_sensor_angular.png
Request Information
Digital pH Sensor Memosens CPS61E
Endress+Hauser
CPS61E-digital-ph-sensor.png
Extended Extended
Request Information
pH/ORP Transmitter Liquisys CPM223
Endress+Hauser
CPM223.png
Request Information
Digital Extension Cable Memosens CYK11
Endress+Hauser
Digital extension cable CYK11
Request Information
Multichannel Transmitter Liquiline CM44P
Endress+Hauser
Liquiline_CM44P_AU.png
Extended Extended
Request Information
Cleaning Injector Chemoclean CYR10B
Endress+Hauser
Cleaning injector Chemoclean CYR10B
Request Information

pH Sensors & Transmitters

pH sensors and transmitters form the backbone of liquid-chemistry monitoring, supporting control of acidity/alkalinity in virtually every water and process stream. pH is frequently a primary quality and safety variable, influencing corrosion, scaling, biological activity, solubility, and reaction kinetics.

Sensor selection is driven by media characteristics and mechanical risk. Glass and enamel electrodes use potentiometric measurement based on electrochemical potential governed by the Nernst relationship, offering broad applicability and strong linearity across the pH range. ISFET sensors use a solid-state transistor-based approach and are applied where glass breakage is unacceptable or where media contain significant organic solvents; enamel electrodes are commonly selected where long-term stability and minimal maintenance are prioritized.

Reliable pH measurement enables stable neutralization control, improved chemical dosing, and faster detection of abnormal conditions in both utilities and product streams. Broad portfolios typically address stable and rapidly changing compositions, sticky or coating-prone media, hazardous-area requirements, and hygienic process needs. Calibration buffers and standardized solutions support traceable measurement practices.

Applications include wastewater neutralization and biological treatment support, chemical manufacturing, food and beverage processes, pharmaceuticals, power and steam-water systems, and mining/metals circuits. pH measurement is also central to CIP/SIP verification and to process steps where small deviations can produce large quality impacts.

Measuring point design focuses on selecting the right junction and reference system, providing suitable mechanical assemblies (flow, immersion, retractable), and planning cleaning and calibration intervals. Automated cleaning and calibration systems can be integrated where measurement integrity must be maintained in aggressive or high-fouling services.

Engineered Equipment Company, a leading supplier of specialized industrial equipment.